Dr. Tiong performs key steps of a laparoscopic living donor nephrectomy with TriSect rapide® 350 and VIO® 3, including – Retroperitoneal incision and mobilization of the descending colon – Fast dissection of the vascular pedicle … Continue reading Laparoscopic living donor nephrectomy using TriSect rapide® and VIO® 3
Disorder of kidney function – EXCEPTIONAL PATIENT STORIES
Mother of Maria, a little girl from Moscow: “Maria is our youngest daughter. When she was born, everything seemed to be fine. After a few months, we began to worry a lot about Maria. She … Continue reading Disorder of kidney function – EXCEPTIONAL PATIENT STORIES
Cystectomy using BiClamp® knife 220
Procedure steps during an open cystectomy with access via a midline incision that can be performed with BiClamp® knife 220: Dissection of the urachus and peritoneal incision alongside the umbilical ligaments Dissection of the Meso … Continue reading Cystectomy using BiClamp® knife 220
Extended PLND for high risk prostate cancer using VIO® 3 preciseSECT
The preciseSECT mode of the VIO® 3 is ideally suited for precise dissection during radical prostatectomy. The video focuses on the anatomical extended pelvic lymph node dissection (PLND) and shows for example the dissection … Continue reading Extended PLND for high risk prostate cancer using VIO® 3 preciseSECT
Radical cystectomy and formation of a neobladder in female patients with BiClamp®
Selected working steps of an open radical cystectomy and formation of a neobladder in female patients are described. The BiClamp 271 T, BiClamp 280 and Bipolar Forceps PREMIUM driven by the Urology Workstation are used … Continue reading Radical cystectomy and formation of a neobladder in female patients with BiClamp®
Cystectomy, laparoscopic, with BiCision®
Vessel sealing and dissection with a single instrument during a laparoscopic cystectomy. BiCision® maximizes the thermofusion zone and minimizes the risk of thermal injury to sensitive structures in urologic surgery, such as ureter or nerves.
Bladder neck exposure during laparoscopic prostatectomy with LAP BiSect Micro
The new LAP BiSect Micro is ideally suited for precise bipolar dissection, e.g.for exposing the bladder neck during a laparoscopic prostatectomy procedure. The BiClamp LAP is used for the sealing of larger vessels.
En-bloc-Resektion von Blasentumoren mit HybridKnife
Mit der elektrochirurgischen Funktion des HybridKnife-Instruments kann der Blasentumor am Stück reseziert werden. Durch die Elevation der Mukosa wird die Resektionsebene angehoben und das Risiko einer Perforation der Muskularis gesenkt.
Bipolar TURP with VIO® 3
Bipolar TURP with the new VIO® 3 mode highCUT bipolar. This new mode has been optimized for bipolar resection in a saline solution. The power peak system (PPS) enables rapid incision. The stable plasma facilitates … Continue reading Bipolar TURP with VIO® 3
Bipolar TURBT with VIO® 3
Bipolar TURBT with the new VIO® 3 mode highCUT bipolar. This new mode has been optimized for bipolar resection in a saline solution. The power peak system (PPS) enables rapid incision. The stable plasma facilitates … Continue reading Bipolar TURBT with VIO® 3
Nerverhaltende radikale Prostatektomie durch Wasserstrahl-Dissektion mit ERBEJET® 2
Die Gewebeselektivität des Wasserstrahls reduziert bei der Prostatektomie das Risiko von Sexual- und Blasenfunktionsstörungen. Blutgefäße und Nervenstränge bleiben bei der Wasserstrahl-Dissektion der Prostata mit dem ERBEJET 2 weitgehend intakt. Die Präparation des Gefäßnervenstranges zwischen Faszie … Continue reading Nerverhaltende radikale Prostatektomie durch Wasserstrahl-Dissektion mit ERBEJET® 2
Prostatectomy, laparoscopic, with ERBEJET® 2
A nerve-sparing laparoscopic prostatectomy with the ERBEJET 2 is shown here. The preparation of the neurovascular bundles between the parapelvic fascia and the prostatic capsule is carried out intermittently using both the waterjet itself and … Continue reading Prostatectomy, laparoscopic, with ERBEJET® 2
Partielle Nephrektomie mit ERBEJET® 2 und Applikator monopolar
Die kombinierte Wasserstrahl-Dissektion und HF-Koagulation mit dem ERBEJET 2 und dem Wasserstrahl-Applikator mit monopolarer HF-Funktion verbessert die OP-Performance bei der Nephrektomie.
Nephrectomy, partial, laparoscopic, with ERBEJET® 2 and BiClamp®
The high-pressure waterjet of the ERBEJET 2 is used for selective dissection of the kidney parenchyma. Where required, the exposed vessels are coagulated, sealed and separated using the BiClamp LAP forceps.
Laparoscopic partial nephrectomy with LAP BiSect Micro
The LAP BiSect enables bipolar laparoscopic exposure of the kidney with a minimum need for equipment and instruments. Easier, quicker, more effective and more cost-efficient. With its excellent preparation properties and effective coagulation and dissection, … Continue reading Laparoscopic partial nephrectomy with LAP BiSect Micro
Nerve sparing laparoscopic radical prostatectomy with hydrodissection, intrafascial technique
Nerve sparing during a laparoscopic radical prostatectomy is crucial for a optimal post-sessional functional outcome. The use of the hydro-dissector ERBEJET® 2 from Erbe during this part of the surgery aids the dissection of the … Continue reading Nerve sparing laparoscopic radical prostatectomy with hydrodissection, intrafascial technique
Laparoscopic retroperitoneal lymphadenectomy with BiCision®
Laparoscopic retroperitoneal lymph node dissection (RPLND) plays an important role in the treatment of testicular cancer. BiCision® is an excellent tool for all steps of this procedure, like preparation, vessel sealing and dissection. The Erbe … Continue reading Laparoscopic retroperitoneal lymphadenectomy with BiCision®