Open hemicolectomy with the new TriSect rapide® 140 and VIO® 3. Speed up your dissection and use decent hemostasis with thermoSECT whenever applicable and get even faster. Dissect sensitive structures and tissues precisely or bluntly … Continue reading Open hemicolectomy with TriSect rapide® 140 and VIO® 3
Laparoscopic sigmoidectomy with TriSect rapide® 350 and VIO® 3
Laparoscopic sigmoidectomy with the new TriSect rapide® 350 and VIO® 3. Plug in TriSect rapide® and enjoy working in a true single step workflow with our customized modes thermoSECT or softCOAG® on your VIO® 3 … Continue reading Laparoscopic sigmoidectomy with TriSect rapide® 350 and VIO® 3
Liver tumor – EXCEPTIONAL PATIENT STORIES
Parents from Yuri, a two-year old boy, from Russia: “Our son was a healthy, happy child. When he became one and a half year old he changed. He no longer played so passionately with his … Continue reading Liver tumor – EXCEPTIONAL PATIENT STORIES
With or without smoke evacuation
Dr. Y. Watanabe demonstrates IES 3, the smoke evacuation system for clean air at your workplace Eliminate surgical smoke with all its potentially dangerous substances from operating rooms, outpatient facilities and medical practices. Smoke evacuation … Continue reading With or without smoke evacuation
Partial liver resection using BiClamp® knife 220
BiClamp® knife 220 is valid for sealing and cutting liver parenchyma during a partial liver resection (segment 4b). BiClamp® knife 220 is operated with VIO® 3 using the thermoSEAL® Mode. The biCLAMP mode expands the … Continue reading Partial liver resection using BiClamp® knife 220
Multivisceral abdominal resection with BiClamp® knife 220
The BiClamp® knife 220 is valid for multivisceral abdominal resection by using the VIO® 3 thermoSEAL® mode. Vessels sealed with BiClamp® knife 220 stand high burst pressure with a short sealing duration. Dissect close to … Continue reading Multivisceral abdominal resection with BiClamp® knife 220
Lateral neck dissection for metastatic thyroid carcinoma using BiClamp® 150 C and Bipolar Forceps PREMIUM
In head and neck surgery selective treatment of vessels is of paramount importance. Erbe bipolar technology therefore is used in ORs around the world for vessel sealing and coagulation. Dedicated VIO® 3 modes like softCOAG® … Continue reading Lateral neck dissection for metastatic thyroid carcinoma using BiClamp® 150 C and Bipolar Forceps PREMIUM
Laparoscopic right hemicolectomy using LAP BiSect Micro and BiClamp® LAP
The LAP BiSect enables laparoscopic right hemicolectomy with a minimum need for equipment and instruments. For excellent dissection, cutting and coagulation, the reusable LAP BiSect Micro offers a wide range of functions and thus makes … Continue reading Laparoscopic right hemicolectomy using LAP BiSect Micro and BiClamp® LAP
Dissection of the colon splenic flexure using the LAP BiSect Micro
The LAP BiSect enables laparoscopic surgery with a minimum need for equipment and instruments. For excellent dissection, cutting and coagulation, the reusable LAP BiSect Micro offers a wide range of functions and thus makes new … Continue reading Dissection of the colon splenic flexure using the LAP BiSect Micro
Waterjet-assisted TEM-ESD of a large-scale rectal adenoma using the Surgery Workstation
Waterjet-assisted TEM ESD using the Surgery Workstation (VIO® 3, ERBEJET® 2, APC 3) combines the advantages of transanal endoscopic microsurgery (TEM) and endoscopic submucosal dissection (ESD). High-pressure waterjet elevation using the ERBEJET® 2 in combination … Continue reading Waterjet-assisted TEM-ESD of a large-scale rectal adenoma using the Surgery Workstation
ToBi – mikroskopische Tonsillektomie mit BiClamp® 150 C
Mikroskopische Gefäßdarstellung und wirksame Gefäßversiegelung mit der BiClamp 150 C führt zu einer neuen Methode der Tonsillektomie ohne Nachblutungen, die Dr. Dr. Jürgen Abrams vorstellt, und die er ToBi nennt.
Thyroidectomy with BiClamp 110
Featuring a special BiClamp dissection technique carried out during a thyroidectomy. The gist of the technique is having a high BiClamp mode setting (E3, modulation 65), adequate tissue tension, thin tissue, and activating the foot … Continue reading Thyroidectomy with BiClamp 110
TEM-ESD using the preciseSECT VIO 3 mode
The preciseSECT VIO 3 mode is particularly well suited to dissect the submucosa during a transanal, microsurgical, endoscopic submucosal dissection, TEM-ESD for short.
Laparoscopic partial splenectomy with BiCision
Surgical procedures, e.g. laparoscopic partial splenectomy, benefit from BiCision‘s sealing quality. BiCision enables you to expose, coagulate, thermofuse and dissect vessels and tissues without changing instruments. The bowl-shaped jaw generates a wider fusion zone than … Continue reading Laparoscopic partial splenectomy with BiCision
Sigmoidectomy, laparoscopic, with BiCision®
Effective and fast mobilization of the large intestine with BiCision® during a laparoscopic sigmoidectomy.
Hemihepatektomie, rechts, mit ERBEJET® 2
Bei der Leberresektion trennt der Wasserstrahl des ERBEJET 2 gewebeselektiv zwischen Parenchym und Blutgefäßen sowie Gallengängen. Weiches Parenchym wird ausgespült, während die Netzstruktur der Blutgefäße erhalten bleibt und blutungsarm versorgt werden kann. Die Eingriffszeit wird … Continue reading Hemihepatektomie, rechts, mit ERBEJET® 2
Gastrectomy, laparoscopic, with BiCision®
During a laproscopic gastrectomy the omentum is separated from the stomach along the greater curvature of the stomach using BiCision®.
Eyelid surgery for entropion using VIO C
The fine power setting of the AUTO CUT and other modes of the VIO C from Erbe provides optimal cutting and preparation results. Please see therefore the surgical treatment of a turned in eyelid (entropion) … Continue reading Eyelid surgery for entropion using VIO C
Chalazion removal with monopolar electrode
The favorable hemostasis properties of the new VIO C mode permit precise dissection and removal of eye cysts (chalazin) using a monopolar tungsten electrode.
Right hemicolectomy with BiCision®
As part of a da Vinci right colectomy the ileocolic artery was transected with BiCision from Erbe.
Liver resection on a newborn child with ERBEJET® 2
Liver resection on a 2-month-old child with ERBEJET® 2 and further instruments from Erbe like the Applicator monopolar, a combination of waterjet with electrosurgery for a faster dissection, BiClamp® 150 C for an effective vessel … Continue reading Liver resection on a newborn child with ERBEJET® 2
Laparoskopische Cholezystektomie mit APCapplicator
Der APCapplicator mit integriertem Filter – breites Applikationsspektrum aus Argonplasma-Koagulation und argonunterstützter Elektrochirurgie. Alles vereint im neuen Einweg Handgriff von Erbe. Besuchen Sie auch apc.erbe-med.com für weitere Informationen
Leberteilresektion mit APCapplicator und Applikator monopolar
Der APCapplicator mit integriertem Filter – breites Applikationsspektrum aus Argonplasma-Koagulation und argonunterstützter Elektrochirurgie. Alles vereint im neuen Einweg Handgriff von Erbe. Besuchen Sie auch apc.erbe-med.com für weitere Informationen
Lobektomie der Lunge mit APCapplicator
Der APCapplicator mit integriertem Filter – breites Applikationsspektrum aus Argonplasma-Koagulation und argonunterstützter Elektrochirurgie. Alles vereint im neuen Einweg Handgriff von Erbe. Besuchen Sie auch apc.erbe-med.com für weitere Informationen
Resektion des Thymus mit APCapplicator
Der APCapplicator mit integriertem Filter – breites Applikationsspektrum aus Argonplasma-Koagulation und argonunterstützter Elektrochirurgie. Alles vereint im neuen Einweg Handgriff von Erbe. Besuchen Sie auch apc.erbe-med.com für weitere Informationen
Hämostase nach Leberteilresektion mit APCapplicator
Der APCapplicator mit integriertem Filter – breites Applikationsspektrum aus Argonplasma-Koagulation und argonunterstützter Elektrochirurgie. Alles vereint im neuen Einweg Handgriff von Erbe. Besuchen Sie auch apc.erbe-med.com für weitere Informationen
Anorectoplasty, external sphincter identification with NT 2
During anorectoplasty (Peña procedure in case of imperforate anus) the superficial and deep layers of the external sphincter are identified by electrostimulation with the NT 2 from Erbe.
TME using the preciseSECT VIO 3 mode
The preciseSECT mode of the VIO® 3 is particularly well suited to mobilize the left colonic flexure and precisly dissect the mesorectum during a total mesorectal excision, TME for short.
Laparoscopic omentectomy using LAP BiSect Micro
The LAP BiSect Micro is an excellent instrument for mobilizing the colon during a hemicolectomy. Bipolar dissection, cutting and coagulation with this instrument enables laparoscopic surgery with a minimum need for equipment and instruments. With … Continue reading Laparoscopic omentectomy using LAP BiSect Micro
Laparoscopic left hepatectomy for HCC with liver cirrhosis using hydrodissection and LAP BiSect Micro
Preventing or controlling hemorrhage during parenchymal transection is the key for laparoscopic hepatic resection. Using the Erbejet 2 for hydrodissection, blood vessels and bile ducts are separated selectively from the parenchyma. Vessels can be treated … Continue reading Laparoscopic left hepatectomy for HCC with liver cirrhosis using hydrodissection and LAP BiSect Micro
Laparoscopic liver resection with ERBEJET 2 and BiClamp LAP
Waterjet dissection combined with the sealing of exposed vessels in a laproscopic liver resection using the straight ERBEJET applicator with suction and the BiClamp LAP Maryland.
Minimal-invasive Thyreoidektomie mit BiClamp® 150 C
Erbe bietet für wichtige OP-Schritte einer Thyreoidektomie ein optimiertes, ergonomisches Instrument an, die BiClamp 150 C. Die Geometrie der Branchen und des Maulteils erlaubt den Eingriff auch bei engen Zugangswegen unter guter Sicht. Die BiClamp … Continue reading Minimal-invasive Thyreoidektomie mit BiClamp® 150 C
Neck dissection, neuromuscular electrical stimulation with NT 2
The spinal accessory nerve (SAN) is an important landmark in the neck. It has a long and superficial course in the posterior cervical neck that makes it vulnerable to injury. Intraoperative localization by electrical stimulation … Continue reading Neck dissection, neuromuscular electrical stimulation with NT 2
Lipoma resection, electrostimulation with NT 2
Intramuscular lipoma of the eyelid. The skin is incised over the lipoma, and the fatty tissue is meticulously dissected away. A nerve test using electrostimulation is performed subsequently with the NT 2.
Living donor right hepatectomy with ERBEJET® 2
Living donor right hepatectomy (LDRH) is currently the most common donor surgery in adult-to-adult living donor liver transplantation (LDLT). Hydrodissection with the ERBEJET 2 is used in this case for – tissue-selective dissection of the … Continue reading Living donor right hepatectomy with ERBEJET® 2
Segmental liver resection with ERBEJET® Applicator Monopolar
Faster dissection in liver surgery The ERBEJET Applicator Monopolar combines waterjet surgery and electrosurgery functions. With the waterjet function, the blood vessels and bile ducts are dissected selectively. As soon as the blood vessels are … Continue reading Segmental liver resection with ERBEJET® Applicator Monopolar